J8005_PE1 · 5069-L306ER · L11C_Label

D Label

Tamp applicator at the blade. Filler delivers a case onto PE4, SV5 enables air, SV6 strokes the tamp, then SQ_Label.ControlBits.0 lets Scanner1 fire. Hand / L’Oréal / Gaylord skip the auto stroke.

D Label · PE1 blade

fill → tamp → scan

Modes

  • Tamp fires from filler ControlBits.2

  • No auto tamp; Ready For Scan stays off

  • Double bag — auto start blocked

  • Gaylord fill — auto start blocked

Stage 5

Tamper extend (seq 20)

SV6 is the Label Tamper Extend valve. GenTimers[1] is “Label Finish Tamp” — the dwell on the case.

Key tags · tap to copy

  1. 1.Seq 20 energizes SV6 (tamp extend).
  2. 2.GenTimers[1] times the finish-tamp dwell.
  3. 3.Timer .DN → seq 30.
EQU(SQ_Label.Num,20)  XIC(SQ_Label.Enable)
OTE(SV6.ControlBits.1)  TON(SQ_Label.GenTimers[1])
XIC(SQ_Label.GenTimers[1].DN)  MOV(30,SQ_Label.Num)

Checks 0/5