CompactLogix 5069-L350ERM · packout

Trace a case from scan to the robot.

LN 10

Interactive field guide for J8005. Pick a lane, walk the life cycle, or start from a symptom. The count drops only when PE10_04 remakes. The robot call is FIFO_DIS through DIS_Job_Seq.

Active lane

Lane 10 conveyor

infeed → packout

robot / packout

Lane 10 tags to watch

Entry / scanner trigger
Accumulation — not in count-down
Discharge interlock — must be clear to start
Discharge confirm — drives the decrement pulse
Live case inventory
Palletizer call bit
Lane number sent to the robot
Robot handshake request / ack

Controller

CompactLogix 5069-L350ERM v31

Count

Case inventory, not lanes remaining

Decrement

DISCHARGE_LN.x AND OutfeedCartonVelXfr[x].2

Confirm PE

PE##04 must clear, then remake

Match

SCNLNx_Buffer EQU WorkOrderLane[x].Number

Robot call

FIFO_DIS → DIS_Job_Seq → SUPER_TO_PALLET[1]

D Label

PE1 SQ_Label · PE4 blade · SV5 air · SV6 tamp